The fence shall be set back in accordance with this title. This calculation shall not include wire strands on top of eight foot fences when permitted under this title. (b) Fences not over eight feet (2,438 mm) high that do not have masonry or concrete elements above six feet (1,829 mm). (E) Permits are required for the installation of plumbing and mechanical systems in any exempt structure. (D) The accessory structure is not required to have fire-resistance-rated exterior walls under the International Building Code and (C) The accessory structure is located in accordance with this title (B) Eaves may extend a maximum of 24 inches past exterior walls, unless the eaves encroach into a setback and/or fire separation distance as defined by the building code, in which case eave extension shall be sized in accordance with the applicable sections in this code and the International Building Code Any usable area of a structure lacking exterior walls under the horizontal projection of a roof shall be included in the structure’s floor area calculation for purposes of this section (A) The floor area within the outside perimeter of the exterior walls area does not exceed 200 square feet (18.6 m 2) and the sidewalls do not exceed 10 feet in height measured from grade average. (ii) Structures under the building code.One- story detached accessory structures not used for human habitation including but not limited to, tool and storage sheds, playhouses, agricultural structures, espresso stands, farm stands, and similar uses, provided: Heating systems are not permitted in accessory structures exempt from a building permit. (D) Permits are required for the installation of plumbing. The clear height is not to exceed five feet for an area greater than 70 square feet of the loft’s framed and sheathed surface and (C) A storage loft is allowed as long as the area of the loft does not exceed one-third the area of the building footprint. (B) Eaves may extend a maximum of 24 inches past exterior walls, unless the eaves encroach into a setback, in which case eave extension shall be sized in accordance with the applicable sections in this code For structures located outside of an UGA, the floor area within the outside perimeter of the exterior walls does not exceed 400 square feet (37.2 m 2), and the sidewalls do not exceed 11 feet in height measured from grade average and have a maximum stud height of 10 feet. (A) For structures located in an urban growth area ( UGA), the floor area within the outside perimeter of the exterior walls does not exceed 200 square feet (18.6 m 2) and the sidewalls do not exceed nine feet in height measured from grade average. (i) Structures under the residential code.One- story detached accessory structures not used for human habitation including but not limited to tool and storage sheds, playhouses, and similar uses, provided: Work exempt under this provision may still require the applicable permit(s) when located in flood hazard or critical areas and be subject to other requirements in this title. Exemption from permit requirements of these codes shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of the building code, residential code, or any other laws or county ordinances. Permits shall not be required for the exemptions listed in this section. This section is included in your selections.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |